BLDUP | The CRE Database

Permit ELC2210909 at 500 Alton Road, Miami Beach, FL, 33139

Issue Date
06/10/22

Type
Permit

Docnumber
ELC2210909

County
Miami-Dade County

Consideration Amount
$10,000,000.00

Description

BC2014976//PRIV PROV INSP ONLY BY MTCI: Description of Work: Installation of light fixtures, lamps and façade lights, fire alarm system, smoke control panel, Area of refugee, Smoke detectors installation, Telephone system service conduit with pull string is included to the closest property line, Conduit with pull string for TV and Data for common areas, Telephone system homerun conduit with pull string, from main phone room to each apartment, is included. Pre-wiring with one four-pair CAT-6 c...BC2014976//PRIV PROV INSP ONLY BY MTCI: Description of Work: Installation of light fixtures, lamps and façade lights, fire alarm system, smoke control panel, Area of refugee, Smoke detectors installation, Telephone system service conduit with pull string is included to the closest property line, Conduit with pull string for TV and Data for common areas, Telephone system homerun conduit with pull string, from main phone room to each apartment, is included. Pre-wiring with one four-pair CAT-6 cable, device plates, jacks (RJ-11) and termination inside of units. CATV system service conduit with pull string is included to the closest property line. CATV system homerun conduit with pull string, from main TV room to each apartment, is included. Pre-wiring with one RG-6 cable, device plates, TV connectors and termination inside of units. Terminal cabinet inside units are included. Phone and TV backboards are included, BDA system, BDA conduits & boxes. Security and access control conduits and boxes. Switch gear system as per plans, Emergency Generator and ATS. Penetrations through sheer walls, transfer beams, tie-beams and tie-columns are necessary and considered to be permitted by structural engineer and building department for slab bed condo unit power, telephone & CATV service conduits. Feeders, Connection of fire pump, jockey pump, domestic water pump, sump pump & elevators are included. Power for elevator pit lights, receptacles, Power for bathrooms exhaust fans (standard ones). Wiring devices including screwless wall plates and decorative style devices (Leviton manufacturer) and tamper proof receptacles inside units and common areas. Standard 5c/18Awg for air hander unit’s thermostats and #14 wire for CUs control. FPL Secondary Service (FPL vault need to be adjacent rooms). Installation of FPL primary conduit only. Trenching and backfilling as necessary for our scope of work. Fire Stopping & Access panels (stealth type)
Read More >>Read Less <<

Fee
213,794.0


(104) Related Documents at 500 Alton Road

To view Related Documents you have to be a FREE BLDUP member.

View All 104 Related Document(s)

Can't Find What You're Looking For?


Browse Other Similar Documents: