2325 North Palethorp Street Overview
Address:
2325 North Palethorp Street
Stories:
3
Contacts (Sign up for PRO to see this --> property's <-- 1 contacts)
Related Projects (6)
View Related Projects With A BASIC Membership
When you upgrade, you get access to all Related Projects.
View Related Projects With A BASIC Membership
When you upgrade, you get access to all Related Projects.
View Related Projects With A BASIC Membership
When you upgrade, you get access to all Related Projects.
View Related Projects With A BASIC Membership
When you upgrade, you get access to all Related Projects.
View Related Projects With A BASIC Membership
When you upgrade, you get access to all Related Projects.
View Related Projects With A BASIC Membership
When you upgrade, you get access to all Related Projects.
Related Documents (6)
EP2021009120
A permit for the amount of was issued on 08/27/21 to Ownership.
Permit Details: INSTALL A 200 AMP ELECTRICAL SERVICE. WIRE THROUGHOUT A NEW SINGLE FAMILY DWELLING: SWITCHES, LIGHTS, RECEPTACLES, TV'S, PHONES, AND INTERCONNECTED SMOKE/CO DETECTORS AS PER 2014 NEC.
Permit Details: INSTALL A 200 AMP ELECTRICAL SERVICE. WIRE THROUGHOUT A NEW SINGLE FAMILY DWELLING: SWITCHES, LIGHTS, RECEPTACLES, TV'S, PHONES, AND INTERCONNECTED SMOKE/CO DETECTORS AS PER 2014 NEC.
MP2021005250
A permit for the amount of was issued on 08/19/21 to Ownership.
Permit Details: EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. (INSTALL ONE (1)- 90% EFF. 60,000 BTU GAS FURNACES EXHAUSTED VIA DIRECT VENT TO THE EXTERIOR (SIDE) INSTALL DUCTWORK, GRILLES, REGISTERS AND DIFFUSERS, INSTALLING ONE 3-TON COIL & ONE 3-TON 13 SEER A/C CONDENSER LOCATED ON A PAD AT THE REAR OF THE BUILDING. (SFD) RP-2021-005453).
Permit Details: EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. (INSTALL ONE (1)- 90% EFF. 60,000 BTU GAS FURNACES EXHAUSTED VIA DIRECT VENT TO THE EXTERIOR (SIDE) INSTALL DUCTWORK, GRILLES, REGISTERS AND DIFFUSERS, INSTALLING ONE 3-TON COIL & ONE 3-TON 13 SEER A/C CONDENSER LOCATED ON A PAD AT THE REAR OF THE BUILDING. (SFD) RP-2021-005453).
FP2021002126
A permit for the amount of was issued on 08/18/21 to Ownership.
Permit Details: FOR INSTALLATION OF A SPRINKLER SYSTEM PER NFPA 13D WITH 1-INCH COMBINED SERVICE LINE AS PER APPROVED PLANS.
Permit Details: FOR INSTALLATION OF A SPRINKLER SYSTEM PER NFPA 13D WITH 1-INCH COMBINED SERVICE LINE AS PER APPROVED PLANS.
PP2021014605
A permit for the amount of was issued on 08/14/21 to Ownership.
Permit Details: EXTERIOR PLUMBING CURB TRAP, FAI, HOUSE DRAIN AND 1 INCH WATER SERVICE INTERIOR PLUMBING 3 WC,3 TUBS, 3 LAVATORIES, 1 KS,1 LL,1 WH
Permit Details: EXTERIOR PLUMBING CURB TRAP, FAI, HOUSE DRAIN AND 1 INCH WATER SERVICE INTERIOR PLUMBING 3 WC,3 TUBS, 3 LAVATORIES, 1 KS,1 LL,1 WH
RP2021005453
A permit for the amount of was issued on 06/28/21 to Ownership.
Permit Details: FOR THE ERECTION OF A THREE (3) STORY ATTACHED STRUCTURE OF TYPE VB CONSTRUCTION FOR USE AS A SINGLE-FAMILY DWELLING. BUILDING TO BE FULLY SPRINKLERED WITH A MINIMUM OF A NFPA 13D AUTOMATIC SPRINKLER SYSTEM. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2015 IRC. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2015 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. PROTECTION OF PEDESTRIANS, PUBLIC RIGHT-OF-WAY, AND ADJACENT PROPERTIES REQUIRED AT ALL TIMES.
Permit Details: FOR THE ERECTION OF A THREE (3) STORY ATTACHED STRUCTURE OF TYPE VB CONSTRUCTION FOR USE AS A SINGLE-FAMILY DWELLING. BUILDING TO BE FULLY SPRINKLERED WITH A MINIMUM OF A NFPA 13D AUTOMATIC SPRINKLER SYSTEM. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2015 IRC. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2015 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. PROTECTION OF PEDESTRIANS, PUBLIC RIGHT-OF-WAY, AND ADJACENT PROPERTIES REQUIRED AT ALL TIMES.
ZP2021004046
A permit for the amount of was issued on 04/30/21 to Ownership.
Permit Details: FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH ROOF DECK AND ROOF DECK ACCESS STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS.
Permit Details: FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH ROOF DECK AND ROOF DECK ACCESS STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS.