20 Canyon Ridge Trail Overview

Permitted Construction:

BLDUP Latest Activity

A permit for the amount of $18,000.00 was issued on 06/16/20 to Ownership.

Permit Details: ALTERNATE SEPTIC FOR 3-BDRM RESIDENCE. R18-9-E309, E304. Installation of a new septic tank and Engineered pad treatment and disposal works to service a 3-bedroom residence with 18 fixture units. Design flow is 450-gallons per day. 5/5 TSS & BOD. System to consist of: 1550 gallon Septic Tank 1- Goulds 10GS05421 Discharge Pump 18 Eljen B43 Modules 51 Tons ASTM C-33 washed sand