1005 North Oak Park Boulevard Overview
Address:
1005 North Oak Park Boulevard
BLDUP Latest Activity
A permit for the amount of $97,547.83 was issued on 01/17/24 to Ownership.
Permit Details: FIRE SPRINKLERS FOR PMTC2022-00154 WITH UNDERGROUND FIRE LINES.
Permit Details: FIRE SPRINKLERS FOR PMTC2022-00154 WITH UNDERGROUND FIRE LINES.
Related Documents (6)
FIRE202300155
A permit for the amount of $97,547.83 was issued on 01/17/24 to Ownership.
Permit Details: FIRE SPRINKLERS FOR PMTC2022-00154 WITH UNDERGROUND FIRE LINES.
Permit Details: FIRE SPRINKLERS FOR PMTC2022-00154 WITH UNDERGROUND FIRE LINES.
PMTC202200154
A permit for the amount of $5,492,989.22 was issued on 11/17/23 to Ownership.
Permit Details: NEW MULTI-PURPOSE BUILDING (41,275 SF) INCLUDES LANDSCAPING, ALL SITE DISABLED ACCESS, SITE LIGHTING AND TRASH ENCLOSURES. (MAJOR GRADING PMTG2022-00051) (BIG FIX#2 - ASB-GRAD22-00002, SEE SPECIAL CONDITON PER CBO). THE GREASE TRAP SHOWN ON THE GRADING PLANS WILL BE REVIEWED AND APPROVED WITH THIS BLDG PERMIT, NOT THE GRADING PERMIT.
Permit Details: NEW MULTI-PURPOSE BUILDING (41,275 SF) INCLUDES LANDSCAPING, ALL SITE DISABLED ACCESS, SITE LIGHTING AND TRASH ENCLOSURES. (MAJOR GRADING PMTG2022-00051) (BIG FIX#2 - ASB-GRAD22-00002, SEE SPECIAL CONDITON PER CBO). THE GREASE TRAP SHOWN ON THE GRADING PLANS WILL BE REVIEWED AND APPROVED WITH THIS BLDG PERMIT, NOT THE GRADING PERMIT.
PMTG202200051
A permit for the amount of $111,517.80 was issued on 07/05/23 to Ownership.
Permit Details: "MAJOR GRADING (104,700 C.Y., 24%, 10.1 ACRES) FOR NEW MULTI-PURPOSE BLDG PAD, PARKING, STORM DRAIN SYSTEM INCLUDING UNDERGROUND BASIN/CHAMBERS, WATER AND SEWER ONLY & AND 580 LF OF SITE WALLS. *** (SEE: PMTC2022-00154 FOR NEW MULTI-PURPOSE BUILDING (41,275 SF) INCLUDES LANDSCAPING, ALL SITE DISABLED ACCESS, SITE LIGHTING AND TRASH ENCLOSURES. THE GREASE TRAP SHOWN ON THE GRADING PLANS WILL BE REVIEWED AND APPROVED WITH THIS BLDG PERMIT, NOT THE GRADING PERMIT.) *** (2/15/23, AS ACTIVE CODE 2016-00375) (NEEDS TO FINAL OTHER (3) ACTIVE GRADING PERMITS, NEEDS OK FROM CJ, CBO OTHERS PRIOR TO ISSUANCE)"
Permit Details: "MAJOR GRADING (104,700 C.Y., 24%, 10.1 ACRES) FOR NEW MULTI-PURPOSE BLDG PAD, PARKING, STORM DRAIN SYSTEM INCLUDING UNDERGROUND BASIN/CHAMBERS, WATER AND SEWER ONLY & AND 580 LF OF SITE WALLS. *** (SEE: PMTC2022-00154 FOR NEW MULTI-PURPOSE BUILDING (41,275 SF) INCLUDES LANDSCAPING, ALL SITE DISABLED ACCESS, SITE LIGHTING AND TRASH ENCLOSURES. THE GREASE TRAP SHOWN ON THE GRADING PLANS WILL BE REVIEWED AND APPROVED WITH THIS BLDG PERMIT, NOT THE GRADING PERMIT.) *** (2/15/23, AS ACTIVE CODE 2016-00375) (NEEDS TO FINAL OTHER (3) ACTIVE GRADING PERMITS, NEEDS OK FROM CJ, CBO OTHERS PRIOR TO ISSUANCE)"
ASBGRAD202200002
A permit for the amount of $139,392.00 was issued on 05/08/23 to Ownership.
Permit Details: AS BUILT MAJOR ENGINEERED GRADING FOR BIG FIX #2 ON TWO PARCELS (18,500 CY, 25%, 1.6 ACRES) TO RECTIFY CODE ENFORCEMENT CASE COD2016-00375, INCLUDES PERMANENT DRAINAGE IMPROVEMENTS @ UPPER BASIN AREA INCLUDING FENCING AND NO UTILITIES." SEE CONDITIONS AFFILIATED WITH PERMITS, PMT2016-07134 - WINTERIZATION PMT2017-00294 - KINDERGARTEN SLOPE PMT2019-00078 - BIG FIX #1 PMTC2022-00154 - MULTI PURPOSE BLDG PMTG2022-00051 - MULTI PURPOSE GRADING
Permit Details: AS BUILT MAJOR ENGINEERED GRADING FOR BIG FIX #2 ON TWO PARCELS (18,500 CY, 25%, 1.6 ACRES) TO RECTIFY CODE ENFORCEMENT CASE COD2016-00375, INCLUDES PERMANENT DRAINAGE IMPROVEMENTS @ UPPER BASIN AREA INCLUDING FENCING AND NO UTILITIES." SEE CONDITIONS AFFILIATED WITH PERMITS, PMT2016-07134 - WINTERIZATION PMT2017-00294 - KINDERGARTEN SLOPE PMT2019-00078 - BIG FIX #1 PMTC2022-00154 - MULTI PURPOSE BLDG PMTG2022-00051 - MULTI PURPOSE GRADING
PMTC202200156
A permit for the amount of $10,105.67 was issued on 03/27/23 to Ownership.
Permit Details: MODULAR CLASSROOM UNIT "B" (1440 SF) FOR PRIVATE SCHOOL, – USED MODULAR SEE SERIAL NUMBER ON THE PLANS (24' X 60'), W/SITE WORK ELECTRICAL, PLUMBING, AND MINOR GRADING (79 CY, 3.3% SLOPE AND .13 ACRES) TRAVELING W/PMTC2022-00155 - (9/21/22 HAS ACTIVE CODE 2016-00375) PER HCD EXEMPT FROM WUI & FIRE SPRINKLERS, SEE RESPONSIBILITIES BELOW, (A) HCD RESPONSIBILITY INCLUDES ALL INTERIOR WORK INCLUDING ELECTRICAL, PLUMBING, HVAC, DISABLED ACCESS FROM THE EXTERIOR SIDING to INSIDE BLDG. INCLUDING (SIGNAGE, DOORS, THRESHOLDS, ETC.) WUI AND FIRE SPRINKLERS WITHIN THE BUILDING. (B) SLO COUNTY RESPONSIBILITIES – FOUNDATIONS, SET-UP, SITE UTILITIES ONLY, SITE DISABLED ACCESS (EXTERIOR) RAMPS, LANDINGS, HANDRAILS UP TO FACE OF STRUCTURE, ETC.) (C) EXEMPT FROM WUI REQUIREMENTS (HCD Bulletin 2009-03 (MH))
Permit Details: MODULAR CLASSROOM UNIT "B" (1440 SF) FOR PRIVATE SCHOOL, – USED MODULAR SEE SERIAL NUMBER ON THE PLANS (24' X 60'), W/SITE WORK ELECTRICAL, PLUMBING, AND MINOR GRADING (79 CY, 3.3% SLOPE AND .13 ACRES) TRAVELING W/PMTC2022-00155 - (9/21/22 HAS ACTIVE CODE 2016-00375) PER HCD EXEMPT FROM WUI & FIRE SPRINKLERS, SEE RESPONSIBILITIES BELOW, (A) HCD RESPONSIBILITY INCLUDES ALL INTERIOR WORK INCLUDING ELECTRICAL, PLUMBING, HVAC, DISABLED ACCESS FROM THE EXTERIOR SIDING to INSIDE BLDG. INCLUDING (SIGNAGE, DOORS, THRESHOLDS, ETC.) WUI AND FIRE SPRINKLERS WITHIN THE BUILDING. (B) SLO COUNTY RESPONSIBILITIES – FOUNDATIONS, SET-UP, SITE UTILITIES ONLY, SITE DISABLED ACCESS (EXTERIOR) RAMPS, LANDINGS, HANDRAILS UP TO FACE OF STRUCTURE, ETC.) (C) EXEMPT FROM WUI REQUIREMENTS (HCD Bulletin 2009-03 (MH))
PMTC202200155
A permit for the amount of $10,263.67 was issued on 03/27/23 to Ownership.
Permit Details: MODULAR CLASSROOM UNIT "A" (1440 SF) FOR PRIVATE SCHOOL, – USED MODULAR SEE SERIAL NUMBER ON THE PLANS (24' X 60'), W/SITE WORK ELECTRICAL, PLUMBING, AND MINOR GRADING (79 CY, 3.3% SLOPE AND .13 ACRES) TRAVELING W/PMTC2022-00156 - (9/21/22 HAS ACTIVE CODE 2016-00375) PER HCD EXEMPT FROM WUI & FIRE SPRINKLERS, SEE RESPONSIBILITIES BELOW, (A) HCD RESPONSIBILITY INCLUDES ALL INTERIOR WORK INCLUDING ELECTRICAL, PLUMBING, HVAC, DISABLED ACCESS FROM THE EXTERIOR SIDING to INSIDE BLDG. INCLUDING (SIGNAGE, DOORS, THRESHOLDS, ETC.) WUI AND FIRE SPRINKLERS WITHIN THE BUILDING. (B) SLO COUNTY RESPONSIBILITIES– FOUNDATIONS, SET-UP, SITE UTILITIES ONLY, SITE DISABLED ACCESS (EXTERIOR) RAMPS, LANDINGS, HANDRAILS UP TO FACE OF STRUCTURE, ETC.) (C) EXEMPT FROM WUI REQUIREMENTS (HCD Bulletin 2009-03 (MH))
Permit Details: MODULAR CLASSROOM UNIT "A" (1440 SF) FOR PRIVATE SCHOOL, – USED MODULAR SEE SERIAL NUMBER ON THE PLANS (24' X 60'), W/SITE WORK ELECTRICAL, PLUMBING, AND MINOR GRADING (79 CY, 3.3% SLOPE AND .13 ACRES) TRAVELING W/PMTC2022-00156 - (9/21/22 HAS ACTIVE CODE 2016-00375) PER HCD EXEMPT FROM WUI & FIRE SPRINKLERS, SEE RESPONSIBILITIES BELOW, (A) HCD RESPONSIBILITY INCLUDES ALL INTERIOR WORK INCLUDING ELECTRICAL, PLUMBING, HVAC, DISABLED ACCESS FROM THE EXTERIOR SIDING to INSIDE BLDG. INCLUDING (SIGNAGE, DOORS, THRESHOLDS, ETC.) WUI AND FIRE SPRINKLERS WITHIN THE BUILDING. (B) SLO COUNTY RESPONSIBILITIES– FOUNDATIONS, SET-UP, SITE UTILITIES ONLY, SITE DISABLED ACCESS (EXTERIOR) RAMPS, LANDINGS, HANDRAILS UP TO FACE OF STRUCTURE, ETC.) (C) EXEMPT FROM WUI REQUIREMENTS (HCD Bulletin 2009-03 (MH))