4100 City Avenue Overview
Address:
4100 City Avenue
Contacts (Sign up for PRO to see this --> property's <-- 1 contacts)
Related Documents (3)
EP2023010823
A permit for the amount of was issued on 11/28/23 to Ownership.
Permit Details: * PROVIDE AND INSTALL (1) 100AMP 3POLE 480VOLT CIRCUIT BREAKERS (MODEL # EGB34100): O (1) CIRCUIT BREAKER IN REPLACEMENT OF HV-R-1 15AMP 3POLE CIRCUIT BREAKER IN PANEL EMDP-2B CIR#'S (14,16,18). * PROVIDE AND INSTALL (1) 80AMP 3POLE 480VOLT CIRCUIT BREAKERS (MODEL # EGB34070): O (1) CIRCUIT BREAKER IN REPLACEMENT OF HV-R-1 15AMP 3POLE CIRCUIT BREAKER IN PANEL EMDP-2A CIR#'S (20,22,24). * INSTALL (1) NEW 80AMP (MCA) CIRCUIT USING 3/3MC CABLE FROM NEW CIRCUIT BREAKER TO NEW DOAS (HV-R-1) UNITS SINGLE POINT POWER CONNECTIONS/INTEGRAL NON-FUSED DISCONNECT SWITCH. (FINAL ROUTING OF CIRCUITS IF NOT WITHIN CURB OF NEW UNITS WILL BE RUN THROUGH ROOF PENETRATIONS PROVIDED BY OTHERS WITH FINAL CONNECTIONS TO UNIT UTILIZING SEALTITE CONDUIT). * INSTALL (1) NEW 60AMP (MCA) CIRCUIT USING 4/3MC CABLE FROM NEW CIRCUIT BREAKER TO NEW DOAS (HV-R-2) UNITS SINGLE POINT POWER CONNECTIONS/INTEGRAL NON-FUSED DISCONNECT SWITCH. (FINAL ROUTING OF CIRCUITS IF NOT WITHIN CURB OF NEW UNITS WILL BE RUN THROUGH ROOF PENETRATIONS PROVIDED BY OTHERS WITH FINAL CONNECTIONS TO UNIT UTILIZING SEALTITE CONDUIT). * RE-CONNECT/EXTEND EXISTING 120VOLT CIRCUITS AND REMOUNT EXISTING LIGHTING IF APPLICABLE TO EACH UNIT (UNIT SUBMITTALS INDICATES 115V GFCI CONVENIENCE RECEPTACLE-UNIT POWERED, PRE-INSTALLED BY MANUFACTURER) DISCONNECT EXISTING HVAC EQUIPMENT AND PROVIDE POWER TO THE NEW HVAC EQUIPMENT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. ** THE SERVICE & PANELS ARE EXISTING.
Permit Details: * PROVIDE AND INSTALL (1) 100AMP 3POLE 480VOLT CIRCUIT BREAKERS (MODEL # EGB34100): O (1) CIRCUIT BREAKER IN REPLACEMENT OF HV-R-1 15AMP 3POLE CIRCUIT BREAKER IN PANEL EMDP-2B CIR#'S (14,16,18). * PROVIDE AND INSTALL (1) 80AMP 3POLE 480VOLT CIRCUIT BREAKERS (MODEL # EGB34070): O (1) CIRCUIT BREAKER IN REPLACEMENT OF HV-R-1 15AMP 3POLE CIRCUIT BREAKER IN PANEL EMDP-2A CIR#'S (20,22,24). * INSTALL (1) NEW 80AMP (MCA) CIRCUIT USING 3/3MC CABLE FROM NEW CIRCUIT BREAKER TO NEW DOAS (HV-R-1) UNITS SINGLE POINT POWER CONNECTIONS/INTEGRAL NON-FUSED DISCONNECT SWITCH. (FINAL ROUTING OF CIRCUITS IF NOT WITHIN CURB OF NEW UNITS WILL BE RUN THROUGH ROOF PENETRATIONS PROVIDED BY OTHERS WITH FINAL CONNECTIONS TO UNIT UTILIZING SEALTITE CONDUIT). * INSTALL (1) NEW 60AMP (MCA) CIRCUIT USING 4/3MC CABLE FROM NEW CIRCUIT BREAKER TO NEW DOAS (HV-R-2) UNITS SINGLE POINT POWER CONNECTIONS/INTEGRAL NON-FUSED DISCONNECT SWITCH. (FINAL ROUTING OF CIRCUITS IF NOT WITHIN CURB OF NEW UNITS WILL BE RUN THROUGH ROOF PENETRATIONS PROVIDED BY OTHERS WITH FINAL CONNECTIONS TO UNIT UTILIZING SEALTITE CONDUIT). * RE-CONNECT/EXTEND EXISTING 120VOLT CIRCUITS AND REMOUNT EXISTING LIGHTING IF APPLICABLE TO EACH UNIT (UNIT SUBMITTALS INDICATES 115V GFCI CONVENIENCE RECEPTACLE-UNIT POWERED, PRE-INSTALLED BY MANUFACTURER) DISCONNECT EXISTING HVAC EQUIPMENT AND PROVIDE POWER TO THE NEW HVAC EQUIPMENT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. ** THE SERVICE & PANELS ARE EXISTING.
MP-2023-002593
A permit for the amount of $469,000.00 was issued on 06/29/23 to Ownership.
Permit Details: ADDITION AND/OR ALTERATIONS. FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
Permit Details: ADDITION AND/OR ALTERATIONS. FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
MP2023002593
A permit for the amount of was issued on 06/29/23 to Ownership.
Permit Details: FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
Permit Details: FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.