1123 West Gurley Street Overview

Permitted Construction:

BLDUP Latest Activity

A permit for the amount of was issued on 01/16/24 to Ownership.

Permit Details: 111-12-003A. ALTERNATE SEPTIC 2 BEDROOM. Installation of new Engineered pad treatment and disposal works to service a 2-bedroom residence with 14 fixture units. Design flow is 300-gallons per day. 5/5 TSS & BOD. System to consist of: 1000 gallon Septic Tank w/o Effluent filter per the Arizona Design and Installation Manual 9/2019, section 6.8 Effluent filters are prohibited). 15 (150 LF) AES (Presby Tubes) Pipe 14 CY ASTM C-33 washed sand or per ADEQ PPL specification in ADEQ PPL dated 9/12/19 31’ x 14’ of stabilizing fabric per MFG if system will be driven over AES pipe may be located under a driveway provided construction conforms to ADEQ PPL dated 9/12/19.