A permit for the amount of was issued on 03/24/22 to Ownership.
Permit Details: FOR INSTALLATION OF HVAC SYSTEM TO THE NEW APARTMENT BUILDING ASPER APPROVED PLANS.
FP2021002779
A permit for the amount of was issued on 01/19/22 to Ownership.
Permit Details: FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM TO INCLUDE A FOUR (4) INCH FIRE SERVICE LINE WITH A 4-INCH WILKINS 350A BACKFLOW PREVENTER AS PER NFPA 13. WORK ALSO TO INCLUDE THE INSTALLATION OF A STANDPIPE SYTEM IN ACCORDANCE WITH NFPA14. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.
FP2022000015
A permit for the amount of was issued on 01/05/22 to Ownership.
Permit Details: ROUGH-IN PERMIT FOR FP-2021-002779 (CP-2020-005479)
EP2021008758
A permit for the amount of was issued on 11/03/21 to Ownership.
Permit Details: Install a 1600 amp service, (2) 16 gang meter banks, (1) 225 amp panel & feeder, (31) 150 amp panels & feeders. install wiring throughout common areas and thirty one units. install lighting normal & emergency, switches, receptacles, provide power for the elevator and the mechanical and emergency equipment. install an addressable fire alarm system throughout. all work in accordance with the 2017 nec & 2016 nfpa-72.
PP2021015271
A permit for the amount of was issued on 09/09/21 to Ownership.
Permit Details: INSTALL BUILDING DRAIN, CURB TRAP, FAI, 3 INCH WATER SERVICE, 30 HOT WATER HEATERS, 30 KITCHEN SINKS, 30 LAUNDRY SINKS, 30 LAVATORIES, 30 SHOWDER/TUBS, 30 WATER CLOSETS AND 3 EJECTOR SUMP PUMP ACCORDING TO THE 2018 PPC.
CP2020005479
A permit for the amount of was issued on 02/22/21 to Ownership.
Permit Details: FOR THE ERECTION OF AN ATTACHED FOUR STORY STRUCTURE WITH ROOF ACCESS STRUCTURE FOR ACCESS TO GREEN ROOF. STRUCTURE FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING THIRTY-ONE (31) DWELLING UNITS AND EIGHTEEN (18) ACCESSORY OFF STREET INTERIOR PARKING SPACES AND ELEVEN (11) OFF STREET BICYCLE (CLASS 1A) PARKING SPACES ON AN ACCESSIBLE ROUTE. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND STANDPIPES TO BE PROVIDED IN THE EXIT STAIRWAYS PER NFPA 14. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 11 FEET OF THE BUILDING FACADE IN ACCORDANCE WITH SECTION 3306 OF THE 2018 IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMIT REQUIRED PRIOR TO THE START OF ANY WORK.*** FIRE WATCH IS REQUIRED ONCE COMBUSTIBLE CONSTRUCTION IS OVER 40 FEET IN HEIGHT, A SITE SAFETY PLAN SHALL BE SUBMITED TO BUILDING INSPECTOR PRIOR TO THE START OF ANY CONSTRUCTION.*** SEPARATE PERMIITS TO BE OBTAINED FOR ALL OTHER WORK.